2015年3月10日星期二

Air circuit breaker Active energy meter

Electrical energy can be converted into a variety of energy. Such as: electric furnace is converted into thermal energy, by the motor into mechanical energy, is converted into light power transformers by the lamp and the like. In these transformations in energy consumption for active energy. The record of this energy meter for active energy meter.
Reactive power meter
Electrical theory tells us that some electrical equipment for energy conversion when served to establish a transition environment, such as: motors, transformers, etc. must first establish a magnetic field in order to make energy conversion, and some electrical device is first made to establish an electric field energy conversion. The establishment of magnetic and electric power are required reactive energy. The record of this power meter for reactive energy meter. Reactive energy in the electrical device itself is not consume energy, but will produce reactive current in the electrical circuit, Air circuit breaker the current will produce a certain loss in the line. Reactive power meter is specifically record this loss, usually only the larger power unit before the installation of such meters.

2015年3月7日星期六

CNC Electric According to the principle of division

1. Meter and electronic sensors into two categories:
Principle of induction meter uses electromagnetic induction to the voltage, current, phase change magnetic moment, pushing aluminum disc rotation axis of the disc (worm) current transformer drive gear drive counters and the drum rotates, the rotation of the process that is the amount of time cumulative process. Therefore, the benefits of induction meter is intuitive, dynamic continuous power does not lose data.
Induction meter high requirements on the process, involving a wide range of material, metal, plastics, precious stones, glass, rare earth and so on, to which the relevant material standard products and requirements are clearly defined, with cheap inferior materials instead of the standard specifications of materials is one of the main problems that affect product quality meter, so like most commodities, low commodity prices will not have a good quality assurance.
Complex production process induction meter, but already mature and stable, but also comprehensive support tooling equipment. Production requirements temperature, humidity and air purification degrees higher.
Electronic energy meter using analog or digital circuits to get the product of voltage and current vector, and then implement the energy measurement functions with analog or lectri calmete digital circuits. Since the application of digital technology, sharing billing meter, prepaid energy meter, multi-user power meter, multifunction power meter have appeared, and further meet the science of electricity and reasonable demand for electricity.
Currently Overall, induction meter, compared with the electronic energy meter, induction meter quantity produced as much. But production of electronic power meters have a clear upward trend.
2. Press the accuracy of measuring the power of classification, there is a general and two tables: one represents meter error does not exceed ± 1%; 2 represents meter error does not exceed ± 2%
3. Press the additional function division, multiple rate meter, prepaid energy meter, energy meter multi-user, multi-function meter, power meter and other carriers. Multi-rate meter or meter, said sharing, multi-rate table, commonly known as peak table, is a measurement instruments in recent years to meet the needs of TOU tariff provided. It can be pre-peak, valley, usually divided into segments, each metering peak, trough, flat section of electricity, and thus different time with different electricity tariffs, tariff regulation play, encourage electricity customers adjust electricity load, peak load shifting, rational use of power resources to fully tap, supply, potential electrical equipment, is an electronic or electromechanical meter; commonly known as prepayment meter card table, with IC card pre-order power, the IC card is inserted in the table can be controlled by the cost of electricity to prevent electricity arrears, is electronic or electromechanical meter; power transformers multi-user meter a watch for multiple users, independent accounting of each user, so you can reach the purpose of saving resources and easy to manage, but also conducive to the centralized remote automatic meter reading, is the electronic energy meter; multifunction meter set a number of functions in one, is the electronic energy meter; carrier Meter use power line carrier technology for centralized remote automatic meter reading, is the electronic energy meter.

2015年3月4日星期三

mcb circuit breaker Meter, ic card meter, and other related products.

  Technical Analysis
The current main program power industry electrical measuring instruments are generally based on semiconductor technology for accurate measurement purposes. Meter generally uses a high-precision A / D converter, the voltage and current signals grid sampling and analog-digital conversion, and Power Supply high-speed digital signal microprocessor for analyzing, processing and data re-processing, sorting, resulting in a variety of measurement data; and finally using a variety of communication interfaces, human-machine interface with a variety of devices to achieve docking.
Meter is a sampling technology, micro-processing technology, design technology and experience combined with the product, is an interdisciplinary high-tech products. Meter manufacturers according to their own understanding and application of design techniques to achieve the function meter. The power meter products, now has a multi-function, networked, intelligent, digital needs, to meet the current requirements of all kinds of measurement, such as measurement of active and reactive power metering, demand computing, grid quality testing, grid event record and other complex functions, and can be used as communication and control from the master data exchange with the central station.
Currently, information collection system product technology is constantly evolving and upgrading process, product requirements and product functionality continuously optimized, mcb circuit breaker increasing to meet the growing information management requirements. Technically mature product combines the current energy metering function, electromagnetic measurement technology, DSP data processing technology, industrial automation technology, wireless remote technology, low-voltage power line carrier communication technology, embedded real-time operating system software platform technologies; interdisciplinary high-tech systemic products are new products,
Meter industry is already mainstream products in the international stage of rapid development, is a sunrise industry, including the world's developed economies and developing countries during the replacement meter to adapt to changes in the current world situation. First, the global energy conservation requirements, the need for accurate measurement of energy, promote the consumption of electricity control subject were based on the change in energy, electricity consumption habits change; the second is to adapt to the power of modern management, information Cncelegroup technology requirements, through smart meter as a node in the grid, you can quickly and efficiently in real-time to understand the situation of electricity power users, substations and other metrology measurement points, provide more accurate service and management.
Meter products in greatest demand are residents of single-phase energy meter, but with each year due to increased electricity consumption, electricity load increases residents, related electrical equipment requires the use of a three-phase power supply. While taking advantage of the three-phase power supply can improve load balancing rates and reduce electricity line losses. At present, most countries have adopted a three-phase residential electricity supply, the scope of application of the three-phase electronic energy meter has gradually expanded from the main field of industrial electricity to the residents of electricity. Therefore, the demand of three-phase power meter measurement will be increasing, accounting in the demand structure in the meter will be increased gradually.
To promote the smart grid construction, smart meter and information collection system will be an important part of the smart grid construction, electricity users to achieve "full coverage, full current transformer collection, full fee control", will facilitate information collection system improve product technology.

2015年2月13日星期五

mcb circuit breaker circuit breaker Daily note

1, to avoid violent vibration, corrosive gases and prevent fluid flow into and prevent under irrigation and dry and ventilated place, do not obstruct ventilation fabric cover.
2, please use the three-plug circuit breaker (grounding) receptacle, grounding screw on the unit must be properly grounded, otherwise the cabinet with a pencil measure would have charged phenomenon, which is caused due to the distributed capacitance induction, is a normal phenomenon, through the ground wire eliminated. If the cabinet serious leakage, measure the insulation resistance is less than 2MΩ, may be an insulating layer is wet or shorted circuit and chassis, should identify the reasons for troubleshooting before use.
3, 0.5 ~ 1.5KVA small power regulator uses fuses for overcurrent circuit protection purposes, 2 ~ 40KVA regulator role DZ47 breaker for over-current, short circuit protection, as is often blown fuse or circuit breaker trips frequently, should check whether the electricity is too large.
4, when the output voltage exceeds the protection level (phase voltage protection value adjusted at the factory 250V ± 5V), power supply automatic protection, cut off the power current transformer supply output voltage, over-voltage lights at the same time, the user should immediately check the grid voltage or shutdown Regulators such as the occurrence of automatic power regulator (with no input output), you should check the mains voltage is higher than 28OV. If less than 280V should check whether the regulator failure. The reason to be identified before use.
5, if the regulator output voltage 220V deviate more, please adjust the potentiometer on the control panel to the normal output voltage (input voltage reach the voltage range can not be adjusted).
6, when the mains voltage is often the input voltage limit (<150V) or upper limit (> 260V) at the regulator, the limit is often affected by micro-switch touch, control failure prone. Then the regulator or the regulator can not only increase (or reduce only), you should first check the micro switch is damaged.
7. Keep the machine clean and dust will hinder rotation of the gear, the impact of the output voltage accuracy. Please contact surfaces clean and maintain coil cleaning. Brush wear serious pressure should be adjusted in order to avoid the contact surface arcing brushes and coils. Brush length less than 2mm should be replaced. Application fine sandpaper to be flat lighting coil arcing burnt black.
Picture ⒏ three-phase voltage regulator regulator input AC Contactors must take over the zero line (neutral), or else the regulator does not work, and will damage the regulator and electrical equipment. Do not use the land line to replace the zero line, zero line can not access the fuse.
9, the regulator output voltage is below the rated voltage (220V or three phase 380V), you should check the input voltage is too low. When you reach the rated voltage at no load and load output below the rated voltage, which is due to the input line carrier surface is too small, too big load line drop, using the input voltage falls below the lower limit of the regulator adjustment range, then should be replaced enter thicker wire.
10, when a large single load power (such as air conditioning, etc.), while the input line is longer, the carrier surface is inadequate when the load is severely reduced operating voltage, it may be difficult to start using load; when the load of work time and temporarily shut down, prone instantaneous overvoltage output power, such as the occurrence of such a phenomenon, not a regulator failure, should improve the input line (bold line, try to shorten the length of the input lines to reduce line pressure drop).
11, when the regulator output voltage is a serious deviation from 220V, you should check whether the input voltage ① within the voltage range; ② motor gear is badly worn, rotation air circuit breaker is flexible; ③ limit switch is damaged: ④ coil plane is smooth; ⑤ Dashboard for damage

2015年2月10日星期二

Air circuit breaker Safety issues

⒈ power supply during power-up, do not open the power supply or teaser power supply input and output connections, to prevent electric shock or other electrical AC Contactors accidents.
⒉ power supply input and output connections must be reasonably arranged to prevent stampede frayed, causing leakage accident.
⒊ power supply must be grounded, because they do not run a ground wire and cause electric shock or personal injury air circuit breaker, the responsibility of the user.
⒋ ground power supply can not be connected to the heating pipes, water pipes, gas pipelines and other public facilities, in order to avoid infringement of third party rights or harm.
⒌ should regularly check the input and output wires of the power supply, so as not to loose or fall off, thus affecting the normal use of power supply and electrical safety.
Optional ⒍ regulator cable must meet requirements can carry enough current capacity of the cable.
. ⒎ regulator should be gently, at work to avoid Circuit Breakers severe vibration;
⒏, ensure regulator carbon brush spring has sufficient pressure to avoid carbon brush arcing contact surface and the coil;
⒐, non-professionals do not open the power supply or power supply repair.
Works
Because section contains electrical coil assembly will produce electricity in the early hinder current eddy currents produced both weaken the instantaneous voltage electrical start-up, resulting in a slow start, will strengthen the instantaneous voltage generated after disconnection, may produce sparks damage circuit. At this point we need a regulator to protect the normal operation of the circuit.
Regulator consists of voltage regulator circuit, a control circuit, and a servo motor, etc., when the input voltage or the load changes, the control circuit sampling, comparing, amplified, and then driving the servo motor, so that the position of the regulator to change the carbon brush, by automatically adjusting the turns ratio, thereby maintaining a stable output voltage. Larger capacity regulator, also adopted the principle of Switchgear & Substation working voltage compensation.

2015年2月7日星期六

CNC Electric AC contactor is a contactor

AC contactor is a contactor, the typical structure is electri calmete divided into direct-acting double break (LC1-D / F *) and single-breaker rotary (LC1-B *). AC contactor and relay control loop combination, remote control or interlock related electrical equipment. The most commonly used products are mainly for CJ series CJX2 series, CJ20 series, CJT1 series 3TB, B series.
The basic composition
AC contactor has four main components: (1) Voltage stabilizer electromagnetic systems, including attracting coil, moving core and static iron core; (2) contact system, including three sets of main contacts and one or two groups of normally open, normally closed auxiliary contacts, which are linked together and moving core linked to each other; (3) interrupter device, usually larger capacity AC contactor has interrupter device to quickly cut off the arc burn from the main contact ; (4) insulated housings and AC Contactors accessories, all kinds of springs, transmission, short ring, terminal and so on.

2015年2月4日星期三

mcb circuit breaker

Works
When the coil is energized, the electromagnetic suction static core, the moving core pull, due to contact with the moving core linkage system, so moving core driven by three runs Switchgear & Substation while moving contacts, contact closure, thereby turning power supply. When the coil is de-energized, suction disappeared, moving core linkage relies in part on the reaction force of the spring and separation, the main contact is open, turn off the power.
Use connection
One: There is generally a three-phase contactor eight points, three inputs, three outputs, there are two control points. Corresponding output and input are easily able to see it. If you want to increase the self-locking, then you also need the output from a terminal point of the line to the control point Circuit breaker on it.
Two: first of all should know the principles of AC contactor. He is outside the power applied to the coil to generate an electromagnetic field. Power-pull, the contact point after power is disconnected. Know principle, you should figure external power supply contact, i.e. two contacts coils, generally in the lower part of the contactor, and at each side. Several other inputs and outputs are generally in the upper part, to see that. Also note that the number of applied voltage power supply (220V or 380V), are generally marked must have. Also note that the point of contact is normally closed or normally open. If you electri calmete have self-locking control, according to the principle haircut line on it.

2015年2月1日星期日

Air circuit breaker Model division

In electrical engineering. A contactor is used to connect or disconnect a DC circuit breakers main circuit or a large capacity with a load control circuit automatic switch, the main control object is a motor, in addition to other electrical loads such as electric heaters, electric welding, lighting equipment, contactors not only turn on and off the circuit, but also has a protective effect of low-voltage release /. Contactor control capacity. Suitable for frequent operation and remote control. Is one of the important components of the automatic control system. Universal contactor can be broadly divided into the following categories.
An AC contactor. Mainly by the electromagnetic mechanism, mcb circuit breaker contact system, interrupter devices and other components. Commonly used CJ10, CJ12, CJ12B series.
2 DC contactor, generally used to control the DC electrical equipment, winding through the DC, the operation principle and structure of the DC contactor AC contactor is basically the same [1].
But now contactor models are re-divided. All of the AC series.
1; AC-1 class contactor is used to control non-inductive or slightly sense circuit.
2; AC - class 2 contact is used to control the start and wound rotor induction motor breaking in.
3; AC-3 and AC - 4 contactor controlled induction Switchgear & Substation motor can be used for frequent starting and breaking.

2015年1月29日星期四

CNC Electric AC contactor can be divided into electromagnetic, permanent magnet and vacuum three.

Categories
Commonly used AC contactor CJ10, CJ40, CJ12, CJ20 and Energy Meter the introduction of CJX, 3TB, B series.
Electromagnetic AC CNC Electric
Contact mainly by electromagnetic system, contact system, arc system and other parts.
① electromagnetic system: electromagnetic system includes an electromagnetic coil and core, is an important part of the contactor, rely on it to drive the contacts closed and disconnected.
② contact system: contacts are operative contacts, including the main contacts and auxiliary contacts. The role of the main contact and breaking the main circuit, control large currents, power transformers and the auxiliary contacts are in the control loop, in order to meet the requirements of various control methods.
③ interrupter system: arc extinguishing means used to ensure that the circuit when the contacts open, arcing reliably extinguished, reduce damage to the arc of contact. In order to quickly extinguish the arc disconnected, usually contactors are equipped with interrupter device, generally semi-sealed longitudinal seam of clay interrupter cover, and with magnetic arc blow circuit.
④ Other parts: an insulating housing, a spring, circuit breakers short-circuit ring, the drive mechanism and the like.

2015年1月26日星期一

mcb circuit breaker Contactor

Works
When the contactor solenoid is not energized, the spring reaction force and the title of the core of the main contacts to keep the weight off position. When the solenoid is Cncelegroup ON-controlled by the control circuit voltage (mcb circuit breaker), the electromagnetic force against the spring reaction force of the armature attracted to the stationary core, drive the main contacts are closed, connected to the circuit, along with the auxiliary contact action.
Permanent magnet AC contactor
Structure
Contactor is mainly driven by the system, contact system, interrupter system and other components.
① drive system: the drive system includes an electronic module, soft iron, permanent magnet, is an important part of the permanent magnet contactor, relying on it to drive the contacts Air circuit breaker closed and disconnected.
② contact system: contacts are operative contacts, including the main contacts and auxiliary contacts. The role of the main contact and breaking the main circuit, control large currents, and the auxiliary contacts are in the control loop, in order to meet the requirements of various control methods.
③ interrupter system: arc extinguishing means used to ensure that the circuit when the contacts open, arcing reliably extinguished, reduce damage to the arc of contact. In order to quickly extinguish the arc disconnected, usually contactors are equipped with interrupter device, generally semi-sealed longitudinal seam of clay interrupter cover, and with magnetic arc blow circuit.
④ Other parts: an insulating housing, Energy Meter a spring, the drive mechanism and the like.

2015年1月23日星期五

Air circuit breaker Feature and Works

Permanent magnet AC contactor is the use of magnetic repulsion of the same principle that opposites attract, and the formation of permanent magnet drive mechanism to replace the Circuit breaker traditional magnet drive mechanism of a micro-power contacts air circuit breaker. Contacts mounted on the linkage of the permanent magnet fixed polar interactions and curing on the contactor base variable soft magnetic polarity to achieve pull, aim to maintain and release. Soft magnetic polarity variable cured together by its electronic module generates a dozen to two dozen milliseconds forward and reverse pulse current, and to produce a different polarity. According to the site required, the electronic control module to control the release of the voltage set value, may be a delay before the reverse pulse current is sent in order to achieve low-voltage time-release or delayed release of the power-off purposes, so that the motor control Akira power from the grid and jump stop, so as to maintain stable production system.
Innovative technical features of the permanent Switchgear & Substation magnet AC contactor with permanent magnet drive mechanism to replace the traditional magnet drive mechanism, namely the use of a permanent magnet and microelectronic modules control devices, replacement of the traditional products of the electromagnetic device, no run current, only by the weak signal current (0.8-1.5mA). Microelectronic module contains six basic parts: a power rectifier; 2. Control power supply voltage detected in real time; 3. Release the storage (some also have pull storage, but not necessarily any); 4. energy storage capacitor voltage. detection; 5. interference threshold voltage detection; 6 release logic. This is a permanent part of the operating mechanism 6 essential part of the composition of the electronic control, the absence of any one part of the operating mechanism will not work under certain circumstances. This six part, will determine the operating Cncelegroup mechanism may have anti-shake electrical function.

2015年1月20日星期二

CNC Electric Energy and no noise:

Traditional contactor closing is maintained by closing the electromagnetic coil is energized opening spring force to overcome to achieve, once the current smaller so that the Inverter Power Supply electromagnetic force generated is insufficient to overcome the spring reaction force, the contactor can not keep closing state Therefore, the conventional AC contactor coil closing maintain that we must rely on electricity to maintain continuous, and this current from tens to thousands of milliamps. The permanent magnet AC contactor closing rely on the permanent magnetic force to maintain, without the need to generate an electromagnetic coil through the current closing force to keep only the electronic module 0.8mA-1.5mA operating current, thus, to maximize savings power, energy-saving rate of over 99.8%.
Traditional AC contactor coil is energized by closing maintain the electromagnetic force to make silicon, silicon pull so happened that when the grid voltage is low or uneven surface or movement silicon dust and foreign matter, there will be noise generation. The permanent magnet AC contactor closing to keep relying on the permanent magnetic force to maintain, so there will be no noise generation.
. ③ no temperature:
Rely on the conventional contactor coil is energized Electric transformer to generate sufficient electromagnetic force to hold the pull coil is composed of a resistor and an inductor, a current is bound to the long-term heat, on the other hand, the magnetic flux passing through the core will produce heat, both heat contactor chamber together in often the contactor coil burned, while reducing the heat capacity of the main contacts. The permanent magnet permanent magnet AC contactor is to rely on force to maintain, without maintaining the coil, naturally there is no temperature rise.
. ④ contacts without chatter:
Retention of traditional AC contactor is energized by the coil to achieve, retention force with current, relevant magnetic gap, when the voltage fluctuations in the closing and opening a critical state, is in a similar close contact like sub-state, it will continue to tremor, causing contact welding or burning, leaving the motor burned out. The permanent magnet AC contactor retention, totally dependent on the permanent magnetic force to achieve a complete pull, voltage fluctuations will not affect the permanent magnetic force, either in the pull-state, or is in the open state, not in the middle of the state, Therefore, Circuit breaker the possibility will not be the main contact chatter and burned, burned the motor is greatly reduced.

2015年1月17日星期六

mcb circuit breaker Long life , high reliability:

Contactor life and reliability is mainly composed of a coil and contact life decisions. Because of the traditional AC contactor coil and core work when it may have a fever, especially voltage, mcb circuit breaker easily lead to fever current, the magnetic gap increases the coil burned, while the permanent magnet AC contactor coil may be burned does not exist. Contact ablation mainly by opening, closing arc generated when due. Compared with conventional contactors mcb circuit breaker, the role of permanent magnet AC contactor in the closing, in addition to the same electromagnetic force, but also with permanent force, thus closing speed is much faster than traditional AC contactor, after testing, permanent magnet AC contactor closing time is generally less than 20ms, while the traditional contactor closing speed is generally about 60ms. Sub-gate, in addition to the permanent magnet AC contactor opening action of the spring, but also has the effect of magnetic repulsion force, these two effects makes opening speed faster than the traditional number of contacts, after testing, permanent magnet AC contactor points opening time is generally less than 25ms, while the traditional contactor opening speed is generally more than 80ms. In addition, the heating coil and core capacity will reduce the main contact, suction voltage fluctuations caused by insufficient or tremor causes fever traditional contactor main contacts, arcing or welding. Permanent magnet AC contactor contact life compared with conventional AC contactor contacts, under the same conditions Voltage stabilizer improve life 3-5 times.
. ⑥ anti-electromagnetic interference:
Permanent magnet AC contactor using magnetic circuit is completely sealed,, in the course will not be subject to external electromagnetic interference, nor will the external electromagnetic interference.
. ⑦ intelligent anti Akira power:
Electronic control module controls the release voltage value can be delayed by a certain time and then send a reverse pulse current to achieve low voltage power-off delay time release or release it from the motor control voltage fluctuations (Akira power) and jump stop, so as to maintain stable production system. Especially the device type continuous production enterprises can reduce venting and resume production of electricity, steam, natural gas Inverter Power Supply consumption and labor costs, equipment repairs and other damage.

2015年1月14日星期三

Air circuit breaker Selection Maintenance

Selection
AC contactor ① Press contactor control objects, the number of operations and the use of categories to select the appropriate category of contacts. ② by using the position CNC Electric of the line of rated voltage selection.
③ Press the load capacity options contactor main contacts rated current.
④ For the attraction coil voltage levels and current type of control power requirements should be considered.
⑤ capacity options for auxiliary contacts, according to the quantity required and interlock loop connected to the contacts consider breaking current size.
⑥ for making and breaking contact with the capacity issues, the choice should pay attention to some of the load using the categories, such as capacitors, tungsten and other lighting device air circuit breaker, when connected to the current value of its large, on-off time is longer, the choice should be left margin.
⑦ for contactor electrical life and mechanical life issues, from the known average number of operations per hour and the life of the machine age, calculate the required electrical life, circuit breakers if it can not meet the requirements should be derated.
⑧ selection should consider the environmental temperature, humidity, vibration using the workplace, dust, chemical corrosion, etc., should be the appropriate choice of different types of contacts environment.
⑨ lighting device is suitable for contacts, should also consider the type of lighting, the starting current size, duration and long-term work starting current, contact the current selection of electrical equipment should not exceed 90% (line) of the rated current. For tungsten and capacitive compensation lighting device, should consider making current value.
⑩ design should be considered a secondary device movement consistency.
Maintain
① operation inspection items: 1) whether the load current through within the contactor ratings in;
2) contactor switching signal indication is consistent with the state of the circuit;
3) Run the sound is normal, whether the issue due electri calmete to poor contact discharge sound;
4) whether the electromagnetic coil overheating, short-circuit ring electromagnet without exception.
5) interrupter cover loose and damage;
6) whether the burning auxiliary contact situation;
7) transmission parts without damage;
8) whether the unfavorable factors in the operating environment to run, such as excessive vibration, poor ventilation, such as excessive dust.
② Maintenance:
When electrical equipment maintenance work should be a contactor and maintenance work.
1) External maintenance:
. a sweeping external dust;
. b Check all fasteners are loose, especially the mcb circuit breaker conductor connecting part, to prevent contact with loose and fever;

2015年1月11日星期日

CNC Electric contact system maintenance:

. a move to check whether the static contact position on the positive, while the three-phase is closed, any questions should be adjusted contact spring;
. b check the contacts wear, abrasion depth Voltage stabilizer of not more than 1mm, contacts have burning, welding off when open, shall be replaced; when slight burning, generally does not affect use. When allowed to use sandpaper to clean the contacts, use plastic file;
. c white insulation resistance measurements, resistance of not less than 10MΩ CNC Electric;
d. Check auxiliary contact action is flexible, shall comply with the value of the contact trip, check whether the contacts fall off, found the problem, it should be repaired or replaced.
3) the core part of the maintenance:
. a clean dust, especially the moving parts and core pull between the contact surfaces;
. b Check the fastening core, the core running loose will cause increased noise;
c. the core short-circuit ring has come off or mcb circuit breaker broken should be promptly repaired.
4) solenoid maintenance:
. a measuring coil insulation resistance CNC Electric;
. b coil insulation discoloration, aging, coil surface temperature should not exceed 65 ° C;
c. Check the coil wire connection, if open welding, burning should be repaired. 5) interrupter cover part of maintenance:
. a check interrupter cover is damaged;
. b interrupter cover and Electric transformer position location without loose change;
c. Remove the metal particles and debris in the arc chute inside the crevice.

2015年1月8日星期四

mcb circuit breaker u low voltage alarm

1. The batteries need to be recharged.
2. Battery voltage is too low or bad, recharge, check the battery terminals, or with a dry cloth to clean the terminals.
u no the inverter output
1. Battery voltage is too low to recharge or replace the battery.
2. Load current is too high mcb circuit breaker, the power transformers closure of some load restart inverter.
3. Inverter over-temperature protection. Let inverter cool for some time, and well ventilated place.
4. The inverter fails to start, restart.
5. Terminals reversed, the fuse is blown, replace the fuse.
u inverter does not work
Check the power switch, fuses and battery cable or cigarette lighter.
Inverters DC input
The reason of such failure often happens is the battery is not connected properly, positive and negative terminals of the inverter must be connected correctly and battery positive and negative, positive then positive, then negative negative, right after connecting the switch is closed, basically you can Electric transformer solve such malfunction.
Inverter input and output fuse
Such failures are generally apparent that, as long as you can replace the fuse.
Battery voltage is higher than the nominal DC input voltage of 20%
The inverter has an operating voltage range, typically rated DC voltage of + -10%, should the higher the voltage, the need to replace batteries or replace the inverter in order to prevent damage to the machine.
Battery voltage is lower than the nominal DC input voltage of 15%
Such problems are mainly due to lack of battery power, you can just give the battery pack.
Load power is too large
Such pre-load problem is caused by lack of AC Contactors power calculation, you need to increase or decrease the power inverter to power the load.